Building Code Of The Day 2/5/2019 Windows (glazing) adjacent or by the bottom stair landings
Submitted by DonHester on Tue, 02/05/2019 - 11:12.
“Building Code Of The Day” Question: Per 2015 IRC For windows (glazing) adjacent or by the bottom stair landings where the window glazing is less than 36” above the landing, how far from the bottom tread are windows required to have safety glazing? A) 24 Inches
B) 36 Inches
C) 48 Inches
D) 60 Inches E) 72 Inches
Answer:
D) 60 inches
? = 60 inches
2015 IRC
Glazing adjacent to the landing at the bottom of a stairway where the glazing is less than 36 inches (914 mm) above the landing and within a 60-inch (1524 mm) horizontal arc less than 180 degrees from the bottom tread nosing shall be considered to be a hazardous location.
Exception: The glazing is protected by a guard complying with Section R312 and the plane of the glass is more than 18 inches (457 mm) from the guard. Information on Safety Glazing https://mybuildingpermit.com/sites/default/files/documentation/Tip%20Sheet%2019%20Safety%20Glazing.pdf
If you find any errors or have additional information that would expand on any code, building standards or manufacturer requirements please let me know.
NCW Home Inspections, LLC is a Licensed Washington State Home Inspection service located in Wenatchee Washington serving Chelan County, Douglas County, Kittitas County, Okanogan County and Grant County Washington and the cities of Wenatchee, Leavenworth, Cashmere, Oroville, Cle Elum, East Wenatchee, Quincy and many more…
Your Wenatchee and Chelan Professional Real Estate, Home and Structural Pest Inspection Service
Instructor- Fundamentals of Home Inspection- Bellingham Technical College